GA Fire Extinguisher

Large Capacity Automatic / Manual Fire Extinguisher GA Series

600 to 4,000 cu. ft.  HFC-227ea and FK-5-1-12 Models Available.

 

  • Designed for larger boats and yachts
  • Protection from 600 cu. ft. to 3,000 cu. ft. (2,000 cu. ft. to 4,000 cu. ft. with FK-5-1-12)
  • Pre-engineered, total flooding system
  • Single and patented two-cylinder linked system design
  • Custom manufactured to order
  • No water or powdery residue
  • 3-Year Limited Warranty
  • USCG, Factory Mutual, ISO RINA, Bureau Veritas Approved
    (USCG approval only goes to 2000 cu. ft.)


Craft with equipment that draws intake air from within a protected space require installation of an Engine Shutdown System.

Download all
pdf

GA1 Series HFC-227ea Owner’s Manual

Size: 1.41 MB
Hits: 1134
Date modified: 01-26-2021
pdf

GA1 HFC-227ea Volume Calculation Worksheet

Size: 211.01 KB
Hits: 581
Date modified: 01-26-2021
pdf

GA Series HFC-227ea Model Selection Chart

Size: 705.95 KB
Hits: 677
Date modified: 05-11-2022
pdf

GA1LK-XX-1D Worksheet

Size: 132.70 KB
Hits: 440
Date modified: 01-26-2021
pdf

GA1LK-XX-XX-3D Worksheet

Size: 140.78 KB
Hits: 410
Date modified: 01-26-2021
pdf

GA2LK-XX-XX-XX-4D Worksheet

Size: 226.11 KB
Hits: 481
Date modified: 01-26-2021
pdf

GA2LK-XX-XX-XX-4D Worksheet

Size: 218.08 KB
Hits: 454
Date modified: 01-26-2021
Download all
pdf

GA Series Product Brochure (GA1 and GA2)

Size: 1.55 MB
Hits: 1778
Date modified: 05-11-2022
pdf

17098_GA-FK-5-1-12_Fireboy 2024.424

Size: 119.65 KB
Hits: 75
Date modified: 07-02-2024
pdf

GA1LKN-XX-XX-3D Worksheet REV C

Size: 115.29 KB
Hits: 50
Date modified: 07-02-2024
pdf

18021F - GA1, FK-5-1-12 - REV G

Size: 1.16 MB
Hits: 24
Date modified: 09-16-2024
pdf

18022F - GA2, FK-5-1-12 - REV G

Size: 1.22 MB
Hits: 34
Date modified: 09-16-2024
pdf

18023F - GA1, FK-5-1-12, 155°F - REV G

Size: 1.16 MB
Hits: 24
Date modified: 09-13-2024
pdf

18024F - GA2, FK-5-1-12, 155°F - REV G

Size: 1.23 MB
Hits: 20
Date modified: 09-13-2024
pdf

18031F - GA1, FK-5-1-12, Manual Only - REV G

Size: 1.03 MB
Hits: 23
Date modified: 09-13-2024
pdf

18032F - GA2, FK-5-1-12, Manual Only - REV G

Size: 1.14 MB
Hits: 24
Date modified: 09-13-2024
pdf

GA2 FK-5-1-12 Volume Calculation REV F

Size: 119.10 KB
Hits: 54
Date modified: 07-02-2024

Fireboy’s GA link allows faster and easier installation with double check-valve quick-connects. This is the first pre-engineered system approved by the USCG for volumes over 1,500 cu. ft.

The Fireboy GA Series is a patented, pre-engineered total flooding fire extinguishing system for protecting larger boats with engine rooms from 600 cubic feet to 4,000 cubic feet.

Each system includes:

  • Single or twin extinguisher cylinders
  • Flexible braided stainless steel hosing
  • One or two overhead temperature sensors
  • Fire-resistant manual release cables
  • Engine shutdown module (sold separately)

GA2 Inside_800

Two or four temperature sensors monitor the engine room temperature 24 hours per day. Two of the temperature sensors are located on the manifold blocks of the cylinders. The remaining one or two temperature sensors are installed above the engines and are linked to the extinguisher cylinders with the flexible hosing.

When the engine room temperature reaches 175°F (79°C) at any of the temperature sensors, the system will completely discharge the clean agent in less than 10 seconds to successfully extinguish the fire. No residue is left behind.

To prevent accidental discharge during shipping and installation, each system is fitted with a patented safety-lock poppet valve. Installation is less costly and less time consuming compared to engineered systems protecting the same volume.

Additionally, no costly third-party certification is required; all certifications are done directly through Fireboy-Xintex.

USCG, Factory Mutual, RINA and Bureau Veritas approved.

Each GA Series system is fitted with a “GA Link” which is flexible, braided 316 stainless-steel hosing with double check valve quick-connect couplings for easy attachment/detachment to the cylinder valve.

When the system is armed, the link is highly pressurized. If the temperature reaches 175°F (79°C) at any of the temperature sensors, a drop in pressure occurs, triggering discharge of the system.

The flexibility of the GA Link allows for easier installation.

No complex piping is required as with many engineered CO2 systems, making the GA Series a viable alternative to more costly and labor intensive systems.

GA Fire Extinguisher - GA Link

GA Series Installation Photos (click to enlarge)

NOTE: Fire extinguisher systems not available online. Please contact Fireboy at 616-735-9380.