Total Flooding Pre-Engineered Fire Extinguishing Systems
Worldwide approved Clean Agent HFC-227ea and FK-5-1-12 Clean Extinguishing Agent. Fireboy clean agent fire extinguisher systems are designed to automatically discharge whenever the protected space ambient temperature reaches 175 degrees Fahrenheit. All systems meet EN ISO 9094-1 and EN ISO 9094-2 standards.
When the Fireboy System discharges, the extinguisher is designed to fully empty the contents in less than 10 seconds. No clean up is required. There is no powdery residue or water left behind. The fire is extinguished by a combination of heat reduction and chemical reaction.
Fireboy Systems are available to protect engine rooms and machinery spaces from as small as 25 cubic feet to as large as 4000 cubic feet.
Each Fireboy pre-engineered fire extinguishing system includes stainless steel mounting brackets, helm station status LED panel and Owners/Installation manual. Backed by our 3-year limited warranty.
All Fireboy Extinguishers are factory refillable except when the discharge is the result of a fire.
Total Flooding Pre-Engineered Fire Extinguisher Systems Approvals:
USCG (MA and MU Series)
USCG (CG and CU Series)
ISO RINA
BSI
MCA Certified
PED BV Final
Bureau Veritas
Factory Mutual
Total Flooding Pre-Engineered Fire Extinguisher Systems Approvals:
USCG (MA and MU Series)
USCG (CG and CU Series)
ISO RINA
BSI
MCA Certified
PED BV Final
Bureau Veritas
Factory Mutual
Fully Automatic
CG Series
Coverage up to
1,000 cu. ft.
Automatic/Manual
MA Series
Coverage up to
1,800 cu. ft.
Automatic/Manual
GA Series
Coverage from
600 cu. ft. to 4,000 cu. ft.
Automatic/Manual
CU/MU Series
Coverage from
25 cu. ft. to 485 cu. ft.
Total Flooding Clean Agent Engineered System FES Series
When properly engineered, these Fireboy Total Flooding Clean Agent Systems fire suppression systems will suppress surface burning fire in Class A, B, and C hazards. Craft with equipment that draws intake air from within a protected space require installation of an Engine Shutdown System.
An engineered system utilizing a fixed nozzle agent distribution network, the system is designed and installed in accordance with the IMO FSS CODE (SOLAS, IMO MSC/ Circ.1267 “Clean Agent Fire Extinguishing Systems”).
When properly designed, the FK-5-1-12 fire extinguishant system will suppress surface burning fire in Class A, B, and C hazards.
80% of FK-5-1-12 fire extinguishant fire fighting effectiveness is achieved through heat absorption and 20% through direct chemical means (action of the fluorine radical on the chain reaction of a flame.
FK-5-1-12 fire extinguishant listings and approvals:
Maritime & Coastguard Agency (MCA)
RINA
Factory Mutual (FM)
Underwriters Laboratories (UL)
NFPA 2001
EPA SNAP
Australian Industrial Chemicals Notification
German Institute for Environmental Hygiene and Medicine
FES System listings and approvals:
USCG
ABS Approval
FES RINA Approval
FES MED – Marine Equipment Directive
MCA Certified
FK-5-1-12 fire extinguishant listings and approvals:
Protects engine rooms and machinery spaces
Coverage up to 17,500 cubic feet
No water
No oily powdery residue
Total flooding system
FES System listings and approvals:
USCG
ABS Approval
FES RINA Approval
FES MED – Marine Equipment Directive
MCA Certified
Marine Carbon Monoxide Alarm CMD6-M
The CMD6-M is the most advanced marine CO alarm on the market, featuring a state-of-the-art sensor that is unaffected by common cleaning solvents.
The ultra low current draw of the new sensor allows us to offer the only marine battery powered CO alarm on the Market. Experience Fireboy-Xintex quality and reliability on board:
Microprocessor controlled
Conformal coated circuit board for added protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
Internal batteries or 12/24V DC models available
CMD6-M Marine and CMD6-R RV Series CO Alarms conform to UL STD 2034, Edition 4
Carbon Monoxide Alarm With New Sensor Technology
Electrochemical sensor – immediate and stablesensing reduces false alarms
Ultra-low current draw – 4 mA
Long sensor life – Approx. 7 year end-of-life (EOL)
Compact design for inconspicuous protection: Modern design blends in with interior decor
Compact design for inconspicuous protection: Modern design blends in with interior decor
Battery operated version requires no power wiring: Reduced labor and material costs to install with maintenance-free lithium-metal batteries
Internal relay module available for generator shutdown or external signal
Interconnect multiple CMD6 CO alarms: All connected CMD6-MxR Alarms sound together
Battery backup on 12/24V DC unit
RCM5 relay control module also available for use with CMD6
Smoke and Fire Alarm - Model SMI100RV
Compact Design: 5.58” Diameter x 1.99” Height
Fast & Easy Installation
9V Battery Powered, No Wiring Required
Low Battery Indicator
Silence Feature
Test Button Easily Accessible on Cover of Alarm
Alarm Horn: 85 dB @ 10 ft
Smoke Sensor: Ionization
Listed to UL217 for RV Use Eighth Edition
Complies with U.S. Coast Guard Sect. 28.325(b)
Gasoline Fume Detectors
Xintex® manufactures and sells vapor-detection instruments to provide positive vapor detection before trouble can develop!
Gasoline fumes in a bilge or engine compartment, with or without a blower fan, have the potential to be a serious risk at any time.
First, because fuel leaks create new fumes as rapidly as the blower clears old fumes away. With the fan off, the hazard is increased.
Second, the blower fan is typically operating prior to engine start-up, thus offering no protection from the ignition of fumes by electrical short circuit, battery hydrogen explosion, smoking or their causes.
Xintex offers a full line of gas detectors and accessories to match your specific needs.